可以采用分体式结构,冷冻机组和箱体分开放置;
箱体顶部开孔,便于电机的吊装;
箱体底部开具4个支撑孔,开模设计软硅胶塞来密封支撑架,避免做低温时结霜及箱体内水的溢出;
中心轴采用特殊密封装置,避免做低温时结霜;
Model | Studio Size(D*W*H)mm | Dimension(D*W*H)mm | |
LRHS-101B-LJS | 450×450×500 | 1170×950×1530 | |
LRHS-225B-LJS | 500×600×750 | 1220×1100×1780 | |
LRHS-504B-LJS | 700×800×900 | 1270×1350×1950 | |
LRHS-800B-LJS | 800×1000×1000 | 1380×1500×2060 | |
LRHS-1000B-LJS | 1000×1000×1000 | 1580×1510×2060 |
Temperature range | A:-20℃~150℃ B:-40℃~150℃ C:-60℃~150℃ D:-70℃~150℃ |
||||||
Temperature uniformity | ≤2℃ (unladen) | ||||||
Temperature fluctuation | ±0.5℃(unladen) | ||||||
Time Setting Range | 1~60000M | ||||||
Humidity range | 20%~98% RH | ||||||
Humidity uniformity | +2% -3% RH | ||||||
Humidity fluctuation | ±2% | ||||||
Heating rate | 1.0~3.0℃/min | ||||||
Cooling rate | 0.7~1.0℃/min | ||||||
Test hole | Mounted on the left side of the machine for use with external test power or signal cables | ||||||
Viewing window | 210×275mm / 395×395mm(effective vision) | ||||||
Outer box material | High quality A3 steel plate electrostatic spraying | ||||||
Inside box material | Imported high-grade stainless steel SUS304 | ||||||
Insulation material | Rigid polyurethane foam + glass fiber | ||||||
Temperature and humidity controller | Adopting Japan “UMC” brand temperature meter | ||||||
Temperature and Humidity Sensor | PT100 Platinum resistance thermometer | ||||||
Cooling method | Single or double cascade refrigeration | ||||||
Compressor | Tecumseh, France | ||||||
Standard configuration | 1 roll of wet bulb gauze, 2 sample racks, with condensate catch pan and drain out of the box | ||||||
Safety | Compressor overpressure overload, over-temperature, fan motor overheating, leakage protection whole machine phase / reverse phase, the whole equipment timing, overload and short circuit protection. | ||||||
Supply Voltage | AC380V±10% 50Hz | ||||||
Power | (A) 3.5kW/4.0kW/6.0kW/8.0kW/9.0kW (B) 4.0kW/4.5kW/7.5kW/9.0kW/10.5kW (C) 4.5kW/6.5kW/9.0kW/13.0kW/13.0kW |
||||||
Operating environment | 5℃~+28℃ ≤85% RH | ||||||
Note: 1、 the above data are in the use of ambient temperature of 25 ℃ and well ventilated conditions measured 2、Can be customized according to the user’s specific test requirements of ice-covered test chamber, ice-covered test chamber, etc. 3、This technical information, subject to change without notice |