A split structure can be adopted, with the refrigeration unit and the box placed separately;
The top of the box is perforated for easy lifting of the motor;
Box bottom has 4 support holes sealed with molded silicone plugs to prevent frost & water overflow.
The central axis adopts a special sealing device to avoid frosting at low temperatures;
Model | Workshop size(D*W*H) mm | External Dimension(D*W*H)mm | |
LRHS-101B-LV | 450×450×500 | 1700×930×1650 | |
LRHS-150B-LV | 500×600×500 | 1800×1080×1650 | |
LRHS-234B-LV | 600×600×650 | 1950×1080×1950 | |
LRHS-512B-LV | 800×800×800 | 2950×1450×2250 | |
LRHS-753B-LV | 970×970×800 | 3130×1620×2250 | |
LRHS-1000B-LV | 1120×1120×800 | 3300×1780×2250 |
Impact temperature range | A-40℃~85℃ B:-55℃~85℃ C:-65℃~85℃ | ||||||
temperature deviation | ±3℃ (at no load) | ||||||
Temperature fluctuation | ≤1℃ (at no load) | ||||||
heating rate | From room temperature to 150℃≤25min (average throughout) (Temperature rise time is the performance of the high temperature chamber when it is operated alone) |
||||||
cooling rate | From room temperature to -55℃≤45min (average throughout) (The cooling time is the performance when the cryogenic box operates alone) |
||||||
Time Setting Range | 1~60000M | ||||||
Sample basket size | 250×250×250mm(100L) 600×600×500mm(512L) 300×400×250mm(150L) 760×760×500mm(753L) 400×400×400mm(234L) 920×920×500mm(1000L) |
||||||
Temperature recovery time | ≤5min | ||||||
Transformation time of the carrycot | ≤15s | ||||||
viewing window | 210 x 275mm or 395 x 395mm (effective field of view) | ||||||
Outer case material | High quality A3 steel plate electrostatic spraying | ||||||
Inner box material | Imported high-grade stainless steel SUS304 | ||||||
Insulation material | Rigid polyurethane foam + fiberglass | ||||||
Temperature Controller | Imported “UEC” brand temperature meter | ||||||
temperature sensor | PT100 platinum resistance temperature measurement body | ||||||
Cooling method | Two-machine cascade refrigeration | ||||||
Compressor | Tycon (France) / BITZER (Germany) | ||||||
standard configuration | Basket sample holder 1 set | ||||||
security protection | Compressor overpressure overload, fan motor overheating, the whole machine under phase / reverse phase Equipment timing, over-temperature, leakage protection, overload and short-circuit protection |
||||||
Supply Voltage | AC380V±10% 50Hz | ||||||
Power | (A)17kW/22kW/25kW/53kW/72kW/95kW (B)17kW/22kW/25kW/53kW/72kW/95kW (C)20kW/25kW/42kW/65kW/85kW/110kW |
||||||
operating environment | 5℃~+28℃ ≤85% RH | ||||||
Note: 1、 the above data are in the use of ambient temperature of 25 ℃ and well ventilated conditions measured 2、Can be customized according to the user’s specific test requirements non-standard thermal shock test chamber, temperature shock test chamber, etc. 3、This technical information, subject to change without notice |