A split structure can be adopted, with the refrigeration unit and the box placed separately;
The top of the box is perforated for easy lifting of the motor;
Box bottom has 4 support holes sealed with molded silicone plugs to prevent frost & water overflow.
The central axis adopts a special sealing device to avoid frosting at low temperatures;
Model | Studio Size (D*W*H)mm | Dimension(D*W*H)mm | |
LRHS-101B-LF | 450×450×500 | 1500×1120×1930 | |
LRHS-225B-LF | 500×600×750 | 1550×1270×2160 | |
LRHS-504B-LF | 700×800×900 | 2000×1470×2290 | |
LRHS-800B-LF | 800×1000×1000 | 1900×1560×2550 | |
LRHS-1000B-LF | 1000×1000×1000 | 2100×1560×2550 |
temperature range | A:-20℃~150℃ B:-40℃~150℃ C:-60℃~150℃ D:-70℃~150℃ |
||||||
Temperature uniformity | ≤2℃ (at no load) | ||||||
Temperature fluctuation | ±0.5℃(at no load) | ||||||
heating rate | atmospheric(100KPa)~1KPa | ||||||
pressure deviation | atmospheric~50Kpa:±2Kpa; | ||||||
heating rate | RT~150℃≤60min (at atmospheric pressure and no load) | ||||||
cooling rate | RT~-40℃≤40min (at atmospheric pressure and no load) | ||||||
decompression time | ≤45min(atmospheric~30KPa) | ||||||
Time Setting Range | 1~60000M | ||||||
Air cooling method | Multi-stage diaphragm air heat exchanger | ||||||
Pressure adjustment method | Dynamic pressure equalization method | ||||||
Outer case material | High quality A3 steel plate electrostatic spraying | ||||||
Inner box material | Imported high-grade stainless steel SUS304, pressure layer using thickened stainless steel reinforcement | ||||||
Insulation material | Rigid polyurethane foam + fiberglass | ||||||
Temperature Controller | Imported “UEC” brand temperature meter | ||||||
temperature sensor | PT100 platinum resistance temperature measurement body | ||||||
Cooling method | Single or double cascade refrigeration | ||||||
Compressor | Tycon, France / BITZER, Germany | ||||||
security protection | Compressor overpressure overload, fan motor overheating, the overall equipment under phase / reverse phase Over-temperature, overall equipment timing, leakage protection, overload and short-circuit protection |
||||||
Supply Voltage | AC380V±10% 50Hz | ||||||
Power | (A)12kW/16kW/20kW/24kW/28kW (B)17kW/22kW/27kW/31kW/35kW (C)20kW/25kW/34kW/38kW/42kW |
||||||
operating environment | 5℃~+28℃ ≤85% RH | ||||||
Note: 1、the above data are in the use of ambient temperature of 25 ℃ and well ventilated conditions measured 2、Can be customized according to the user’s specific test requirements of high, low temperature and low pressure test chamber non-standard 3、This technical information, subject to change without notice |