A split structure can be adopted, with the refrigeration unit and the box placed separately;
The top of the box is perforated for easy lifting of the motor;
Box bottom has 4 support holes sealed with molded silicone plugs to prevent frost & water overflow.
The central axis adopts a special sealing device to avoid frosting at low temperatures;
Pseudolaric acid | Pendulum tube rain test device | |
waterproof rating | IPX3、IPX4 |
Oscillating tube water jet aperture | ø0.4mm | ||||||
Pendulum Angle Amplitude | ±45°、60°、135°、150°、175°(theoretical values) | ||||||
radius of the pendulum | R=200mm、400mm、600mm、800mm(either one or the other) | ||||||
Pendulum speed | 25°~45°/s | ||||||
drenching pressure | 80~100(Adjustable) | ||||||
water flow | 0.07L/min per hole (±5%) | ||||||
Spraying water | Clean, soft tap water | ||||||
Test bench size | ø600mm | ||||||
Rotational speed of test bench | 1-3r/min(Adjustable) | ||||||
Time Setting Range | 1~9999H | ||||||
Temperature Controller | “Taiwan Weilun” touch screen + ‘Germany Siemens’ PLC module | ||||||
water pump | Provision of a pressurized test water source | ||||||
Table rotation | The motor drives the turbine to decelerate and rotate to achieve the effect of low speed and high torque | ||||||
Nozzle | The nozzle is a detachable special nozzle | ||||||
security protection | Fan motor overheating, overall equipment under phase/reverse phase Integral equipment timing, leakage protection, overload and short circuit protection |
||||||
Supply Voltage | AC220V±10% 50Hz | ||||||
Note: 1, according to the user’s specific requirements of non-standard customized pendulum rain test device, etc. 2、This technical information, if there is any change without prior notice |