A split structure can be adopted, with the refrigeration unit and the box placed separately;
The top of the box is perforated for easy lifting of the motor;
Box bottom has 4 support holes sealed with molded silicone plugs to prevent frost & water overflow.
The central axis adopts a special sealing device to avoid frosting at low temperatures;
Pseudolaric acid | waterproof rating | |
Flush test device | IPX5、IPX6 |
Spraying aperture | ø6.3mm & ø12.5mm | ||||||
water spray pressure | 30kpa and 100kpa (reference value, subject to flow rate) | ||||||
water spray | 12.5±0.625L/min vs. 100±5L/min | ||||||
Test time | Minimum 3min | ||||||
Structure of the test device | By the water storage tank, pressurized water pump, regulating and reducing valve, flow regulator, pressure gauge, water pipe Diversion device and spray bracket (shared with the sprinkler rosette device) electrical control box and other components |
||||||
water-storage tank | Made of thickened high-grade brushed stainless steel with argon arc welding. | ||||||
Spray bracket | Made of stainless steel finishing | ||||||
security protection | Overall equipment under-phase/reverse-phase, test timing, leakage protection, short-circuit protection | ||||||
Supply Voltage | AC380V±10% 50Hz | ||||||
Note: 1, according to the user’s specific test requirements non-standard customized nozzle splash test device, etc. 2、This technical information, if there is any change without prior notice |