A split structure can be adopted, with the refrigeration unit and the box placed separately;
The top of the box is perforated for easy lifting of the motor;
Box bottom has 4 support holes sealed with molded silicone plugs to prevent frost & water overflow.
The central axis adopts a special sealing device to avoid frosting at low temperatures;
Model | Studio Size (D*W*H)mm | Dimension(D*W*H)mm |
LRHS-672-NGF | 700×800×1200 | 1030×1580×2150 |
light source drive | EPS | |
Effective irradiance area | 800mm×700mm | |
Distance of light source from test surface | 1000±200mm | |
Light source power | 2000W/lamp | |
Number of light sources | 1PCS | |
Light intensity range | 150~250W/m2 | |
spectral range | 280~320nm 320~400nm | |
UVB/(UVA+UVB) | 5 to 8% | |
inhomogeneity | ≤10% | |
UVC Content | (Ratio of integrated irradiance in the wavelength range (250-280) nm to integrated irradiance in the wavelength range (250-400) nm of UVC content ≤1%. | |
Sample temperature range | 60~70℃ (customized water-cooled structure for cell carrier table) | |
Sample temperature deviation | ≤±2℃ | |
Chamber temperature range | 20~80℃ | |
Box temperature fluctuation | ≤1℃ | |
Outer case material | 1.2mm Cold rolled steel plate with plastic spraying on both sides | |
Inner box material | 1.0mm thick SUS304 stainless steel, sunlight simulating fully reflective reflective film mounted on the side wall for secondary sealing and optical reflection control. | |
Insulation material | 10mm Thickness High Quality Insulation Material | |
Controller | Siemens PLC Module + Touch Screen | |
Cooling method | Air-cooled refrigeration | |
Compressor | Taikang, France | |
Heating method | Nickel-chromium alloy electric wire type heater | |
light source | Holler lamp, metal halide wick, European brand. Warranty time of the light source 2000 hours, the actual use of time greater than or equal to 3000 hours |
|
irradiance meter | Alberdi Brands | |
security protection | Emergency stop button, sample surface temperature is too high, light source system fault alarm, power supply phase/undervoltage/overvoltage/leakage protection, fan overload, compressor overvoltage/overheat/overcurrent, heating wire over-temperature protection | |
Supply Voltage | Voltage: 3/N/PE AC 400V±10% 50Hz Rated current: 30A | |
Power | 20.0kW | |
operating environment | 10℃~+35℃ ≤75% RH | |