A split structure can be adopted, with the refrigeration unit and the box placed separately;
The top of the box is perforated for easy lifting of the motor;
Box bottom has 4 support holes sealed with molded silicone plugs to prevent frost & water overflow.
The central axis adopts a special sealing device to avoid frosting at low temperatures;
Studio Size (D*W*H)mm | 5500×3000×2800(D*W*H)mm | ||||||
Dimension(D*W*H)mm | 6250×3200×3300(D*W*H)mm | ||||||
temperature range | -40℃~60℃ | ||||||
Humidity range | 20%~80%RH | ||||||
Rate of temperature change | 25℃~-40℃≤2.5H 25℃~60℃≤2H | ||||||
Temperature control accuracy | ±1℃(at no load) | ||||||
temperature deviation | ±2℃(at no load) | ||||||
Outer case material | High-quality assembled library board, beautiful, easy to clean | ||||||
Inner box material | Imported high-grade stainless steel SUS304 | ||||||
Floor construction | Non-slip stainless steel, thickness ≥ 3mm, ground bearing capacity of 1200kg / wheel | ||||||
Temperature Controller | Imported “UEC” brand temperature and humidity meter | ||||||
temperature sensor | PT100 platinum resistance temperature measurement body | ||||||
Humidity Sensor | Imported electronic humidity sensor | ||||||
Cooling method | Two-machine cascade refrigeration | ||||||
Compressor | Tycon (France) / BITZER (Germany) | ||||||
Supply Voltage | AC380V±10% 50Hz | ||||||
Maximum vehicle size | customizable | ||||||
Maximum equipment weight | customizable | ||||||
Maximum engine power | 300kW | ||||||
Maximum suction capacity of the whole vehicle | 720m3/h | ||||||
Maximum exhaust capacity of the whole vehicle | 3200m3/h | ||||||
Maximum heat dissipation of the whole vehicle | 300kW | ||||||
Maximum temperature at exhaust outlet | 350℃ | ||||||
Note: 1、the test data are used in the ambient temperature of 25 ℃ and well ventilated conditions measured 2、The above parameters are for reference only, and can be customized according to user-specific test parameters. 3、This technical information, subject to change without notice |