A split structure can be adopted, with the refrigeration unit and the box placed separately;
The top of the box is perforated for easy lifting of the motor;
Box bottom has 4 support holes sealed with molded silicone plugs to prevent frost & water overflow.
The central axis adopts a special sealing device to avoid frosting at low temperatures;
Model | Studio Size (D*W*H)mm | Dimension(D*W*H)mm | |
LRHS-2000D(R15)-LJS | 1000×2000×1000 | Subject to contractual three-view | |
LRHS-4000D(R15)-LJS | 2000×2000×1000 | ||
LRHS-6000D(R15)-LJS | 2000×3000×1000 | ||
LRHS-8000D(R15)-LJS | 2000×2000×2000 |
temperature range | A:-20℃~150℃ B:-40℃~150℃ C:-60℃~150℃ D:-70℃~150℃ |
||||||
Temperature uniformity | ≤2℃ (at no load) | ||||||
Temperature fluctuation | ±0.5℃ (at no load) | ||||||
Humidity range | 20%~98% RH | ||||||
Humidity uniformity | +2% -3% RH | ||||||
Humidity fluctuation | ±2% | ||||||
heating rate | -55℃~125℃ Linear 15℃/min (at no load) | ||||||
cooling rate | 125℃~-55℃ Linear 15℃/min (at no load) | ||||||
Time Setting Range | 1~60000M | ||||||
test hole | Mounted on the left side of the machine for use with external test power or signal cables | ||||||
viewing window | 395 x 395mm (effective field of view) | ||||||
Outer case material | High quality A3 steel plate electrostatic spraying | ||||||
Inner box material | Imported high-grade stainless steel SUS304 | ||||||
Insulation material | Rigid polyurethane foam + fiberglass | ||||||
Temperature Controller | Imported “UEC” brand temperature and humidity meter | ||||||
temperature sensor | PT100 platinum resistance temperature measurement body | ||||||
Cooling method | Two-machine cascade refrigeration | ||||||
Compressor | France Tycon/Germany Bitzer/Germany Copeland | ||||||
standard configuration | Equipped with a condensate catch pan and discharged out of the box | ||||||
security protection | Compressor overpressure overload, fan motor overheating, the whole machine under phase / reverse phase Timing, over temperature, leakage protection, overload and short-circuit protection |
||||||
Supply Voltage | AC380V±10% 50Hz | ||||||
operating environment | 5℃~+28℃ ≤85% RH | ||||||
Note: 1、 the model in the R represents linear, r represents non-linear, the number in parentheses represents the cooling rate 2、Test data are measured in the use of ambient temperature of 25 ℃ and well ventilated conditions 3、Above parameters are for reference only, can be customized according to user-specific test parameters 4、This technical information, subject to change without notice |