A split structure can be adopted, with the refrigeration unit and the box placed separately;
The top of the box is perforated for easy lifting of the motor;
Box bottom has 4 support holes sealed with molded silicone plugs to prevent frost & water overflow.
The central axis adopts a special sealing device to avoid frosting at low temperatures;
Model | Studio Size (D*W*H)mm | Dimension(D*W*H)mm | |
LRHS-225-WSZ | 500×600×750 | Subject to contractual three-view | |
LRHS-1000-WSZ | 1000×1000×1000 | ||
LRHS-2000-WSZ | 1000×2000×1000 | ||
LRHS-8000-WSZ | 2000×2000×2000 |
temperature range | -60℃~150℃ | ||||||
Temperature uniformity | ≤2℃ (at no load) | ||||||
Temperature fluctuation | ±0.5℃(at no load) | ||||||
Time Setting Range | 1~60000M | ||||||
Humidity range | 20%~98% RH | ||||||
Humidity uniformity | +2% -3% RH | ||||||
Humidity fluctuations | ±2% | ||||||
heating rate | 1.0~3.0℃/min | ||||||
cooling rate | 0.7~1.0℃/min | ||||||
Lifting platform | Lifting platform method to adjust the height of the test chamber | ||||||
viewing window | 210 x 275mm or 395 x 395mm (effective field of view) | ||||||
sinusoidal thrust | ≥2200kN | ||||||
random thrust | ≥2200kN | ||||||
Impact thrust (6ms) | ≥4400kN | ||||||
frequency range | DC~3000Hz | ||||||
sustained displacement | 45mm(p-p) | ||||||
shock displacement | 45mm(p-p) | ||||||
Maximum speed | 1.5~2.5m/s | ||||||
maximum acceleration | 950m/s² | ||||||
First order resonant frequency | 2600Hz | ||||||
Allowable eccentricity moment | >500N×m | ||||||
load junction | 16 connections | ||||||
Axial vibration isolation frequency | <3Hz | ||||||
Maximum load | 300kg | ||||||
Countertop Size | 600mm×600mm | ||||||
Maximum load | 300kg | ||||||
Outer case material | High quality A3 steel plate electrostatic spraying | ||||||
Inner box material | Imported high-grade stainless steel SUS304 | ||||||
Insulation material | Rigid polyurethane foam + fiberglass | ||||||
Temperature Controller | Japan’s original imported “UEC” brand temperature meter | ||||||
temperature sensor | PT100 platinum resistance temperature measurement body | ||||||
Cooling method | Two-machine cascade refrigeration | ||||||
Compressor | Tycon (France) / BITZER (Germany) | ||||||
security protection | Compressor overpressure overload, over temperature, fan motor overheating, leakage protection Machine under-phase/reverse-phase, test timing, overload and short circuit protection. |
||||||
Supply Voltage | AC380V±10% 50Hz | ||||||
Power | 24.0kW/48.0kW/60.0kW/85.0kW | ||||||
operating environment | 5℃~+28℃ ≤85% RH | ||||||
Note: 1、 the test data are used in the ambient temperature of 25 ℃ and well ventilated conditions measured 2、The above parameters are for reference only, and can be customized according to user-specific test parameters. 3、This technical information, subject to change without notice |