Cyclic salt spray corrosion test chamber more realistically simulate the natural climate of the material in the endurance of the usual actual atmospheric exposure there are two kinds of wet and dry conditions, accelerated laboratory testing to simulate natural cycling conditions to make sense. Studies have shown that in cyclic corrosion testing, the relative corrosion rate, structure and morphology more similar to the outdoor situation. Therefore, compared to conventional salt spray testing, cyclic testing is usually more comparable to outdoor conditions.

Service Hotline

4000-662-888
Product Features
Product Parameter
Model Studio Size  (D*W*H)mm Dimension(D*W*H)mm
LRHS-108-RFHY 450×600×400 Subject to contractual three-view
LRHS-270-RFHY 600×900×500
LRHS-412-RFHY 750×1100×500
LRHS-663-RFHY 850×1300×600
LRHS-816-RFHY 850×1600×600
LRHS-1080-RFHY 900×2000×600
temperature range 0℃~60℃
Humidity range 30%~98% RH
Saturated drum temperature RT+10℃~70℃
Temperature uniformity ≤2℃ (at no load)
Temperature fluctuation ±0.5℃(at no load)
Salt spray deposition 1~2ml/80 cm².h(16-hour average)
heating rate 0.5℃~1.5℃/min
cooling rate 0.5℃~1.0℃/min
Compressed air pressure 2.00±0.01(kg/cm²)
Spraying method Continuous/periodic selectable
Specimen holder angle Can meet 15°, 30° tilt test
Test Methods NSS test AASS test CASS test
Case Material PP reinforced rigid plastic sheet or 316 stainless steel
Lid Material PP reinforced rigid plastic sheet or 316 stainless steel
Air-saturated drums Imported high-grade stainless steel SUS304
Pressurized Air Hose Material High quality rubber hose
Other pipelines Thickened Fluorosilicone Rubber Tubing
Temperature Controller Imported “UEC” brand temperature meter
Dehumidification and cooling Single or double cascade refrigeration
Compressor Taikang, France
temperature sensor PT100 platinum resistance temperature measurement body
heater Titanium Heating Tube
interrupter Schneider miniature circuit breakers (to prevent short circuits in control circuits)
standard configuration V-shaped sample holders, round rods, nozzles, funnels, metering cylinders, mist evacuation tubes
security protection Over-temperature, under-phase/reverse-phase, test timer, fast mist removal indication, test end
Low water level protection, leakage, short circuit, overpressure overload compressor
Supply Voltage AC380V±10% 50Hz
Power 8.5kW/10.0kW/12.0kW/13.5kW/15.0kW/17.5kW
operating environment 5℃~+28℃ ≤85%RH
Note:
1、 the test data are used in the ambient temperature of 25 ℃ and well ventilated conditions measured
2、Can be customized according to the specific requirements of the user non-standard cyclic salt spray corrosion test chamber etc
3、This technical information, subject to change without notice

 

Product Recommendation
Industry News
In the workshops of some enterprises, we often see a brand-new constant temperature and humidity test chamber that, after a short period of use, becomes covered in oil stains and dust.
Previously, we have discussed many technical aspects of temperature cycling test chambers. Today, we will share methods for detecting leaks in these chambers. Specifically, there are four main approaches to check for leaks.
The safety of low-temperature test chambers during operation is of utmost importance. Not only must environmental safety measures be in place, but proper operational protocols must also be followed.